Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 308
Filtrar
1.
Dis Colon Rectum ; 65(2): e80-e84, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34840298

RESUMO

BACKGROUND: Curvilinear array ultrasound transducers enable tissue sampling and have therapeutic capabilities. Nevertheless, colonic intubation and maneuvering with these transducers is technically challenging and is therefore typically limited to the rectosigmoid area. This retrospective cohort study aimed to evaluate the safety, feasibility, and diagnostic yield of colonoscopic ultrasound-guided fine-needle aspiration in deep colonic intubation. IMPACT OF INNOVATION: The impact of this innovation is to enable tissue sampling of colonic and extracolonic lesions guided by endoscopic ultrasound. TECHNOLOGY, MATERIALS, AND METHODS: Curvilinear array ultrasound is used in the evaluation of luminal and extraluminal colonic diseases. Thirteen patients underwent colonoscopic ultrasound with a curvilinear array ultrasound endoscope in a single center for subepithelial lesions, cancer staging, and extracolonic lesions from July 2015 to February 2021. Endosonography was performed using an Olympus EU-ME1 and GF-UCT 180 with a 5-12MHz curvilinear array transducer. The primary outcome was the percentage of patients who were successfully scanned with the endoscopic ultrasound. The secondary outcomes included the success rate of fine-needle aspiration, the diagnostic yield of the tissue samples, and the adverse events related to the procedure. PRELIMINARY RESULTS: A total of 13 female patients underwent colonoscopic ultrasound. All patients (100%, 13/13) were successfully scanned. Fine-needle aspiration was deemed necessary and successfully performed in 100% (5/5) of the patients. Tissue samples collected by fine-needle aspiration resulted in a diagnostic yield of 60%, and no adverse events resulted from this intervention. CONCLUSIONS: This study demonstrates the feasibility of performing colonoscopic ultrasound with a curvilinear array transducer. Fine-needle aspiration for subepithelial, colonic, and extracolonic lesions is feasible and safe in this setting with no adverse events reported in our study. FUTURE DIRECTIONS: Future research should be directed toward validating colonoscopic ultrasound with a curvilinear array transducer technique in prospective randomized trials. Studies evaluating the feasibility and safety of endoscopic ultrasound-guided interventions in the colon, such as abscess drainage and enteral anastomosis, should be considered.


Assuntos
Doenças do Colo/patologia , Colonoscopia/instrumentação , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Endossonografia/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças do Colo/diagnóstico por imagem , Colonoscopia/efeitos adversos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Endossonografia/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
2.
Technol Cancer Res Treat ; 20: 15330338211043040, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34605316

RESUMO

Objective: The accuracy of rapid on-site evaluation (ROSE) during endobronchial ultrasonography with guide sheath (EBUS-GS) was reported to be approximately 90% for diagnosing small peripheral pulmonary lesions (PPLs). When ROSE during EBUS-GS for diagnosing small peripheral lung cancer is carried out and does not include malignant cells in a position whereby the probe was located within or adjacent to the lesion, the best technique for overcoming the lower diagnostic yield remains unknown. This study aimed to evaluate factors affecting positive results of ROSE during EBUS-GS in such a probe position. Moreover, when the results of ROSE were consistently negative, we evaluated the effectiveness of conventional transbronchial biopsy (TBB) in addition to EBUS-GS alone. Methods: We performed a retrospective analysis of consecutive patients who underwent EBUS-GS combined with ROSE for diagnosing small peripheral lung cancer (≤30 mm). We classified the results of ROSE into two groups based on the presence of malignant cells: the ROSE positive group (included malignant cells) and the ROSE negative group (did not include malignant cells). The significant predictors of positive ROSE results during EBUS-GS were analyzed using multivariate logistic regression analyses. Results: We identified 67 lesions (43 lesions in the ROSE positive group and 24 lesions in the ROSE negative group, respectively). Multivariate logistic analysis revealed that the significant factor affecting positive ROSE results was lesion size (>15 mm) (OR = 9.901). The diagnostic yield of additional conventional TBB to EBUS-GS was significantly higher than that of EBUS-GS alone (75.0% vs 33.3%, P = .041). Conclusion: The positive results of ROSE during EBUS-GS were significantly influenced by lesion size (>15 mm). When the results of ROSE during EBUS-GS were consistently negative in a position whereby the probe was located within or adjacent to the lesion, additional conventional TBB was effective to improve the diagnostic yield compared with EBUS-GS alone.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Avaliação Rápida no Local , Adulto , Idoso , Idoso de 80 Anos ou mais , Broncoscopia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Endossonografia , Feminino , Humanos , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Carga Tumoral
3.
Gastroenterology ; 161(3): 899-909.e5, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34116031

RESUMO

BACKGROUND AND AIMS: The benefit of rapid on-site evaluation (ROSE) on the diagnostic accuracy of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) has never been evaluated in a randomized study. This trial aimed to test the hypothesis that in solid pancreatic lesions (SPLs), diagnostic accuracy of EUS-FNB without ROSE was not inferior to that of EUS-FNB with ROSE. METHODS: A noninferiority study (noninferiority margin, 5%) was conducted at 14 centers in 8 countries. Patients with SPLs requiring tissue sampling were randomly assigned (1:1) to undergo EUS-FNB with or without ROSE using new-generation FNB needles. The touch-imprint cytology technique was used to perform ROSE. The primary endpoint was diagnostic accuracy, and secondary endpoints were safety, tissue core procurement, specimen quality, and sampling procedural time. RESULTS: Eight hundred patients were randomized over an 18-month period, and 771 were analyzed (385 with ROSE and 386 without). Comparable diagnostic accuracies were obtained in both arms (96.4% with ROSE and 97.4% without ROSE, P = .396). Noninferiority of EUS-FNB without ROSE was confirmed with an absolute risk difference of 1.0% (1-sided 90% confidence interval, -1.1% to 3.1%; noninferiority P < .001). Safety and sample quality of histologic specimens were similar in both groups. A significantly higher tissue core rate was obtained by EUS-FNB without ROSE (70.7% vs. 78.0%, P = .021), with a significantly shorter mean sampling procedural time (17.9 ± 8.8 vs 11.7 ± 6.0 minutes, P < .0001). CONCLUSIONS: EUS-FNB demonstrated high diagnostic accuracy in evaluating SPLs independently on execution of ROSE. When new-generation FNB needles are used, ROSE should not be routinely recommended. (ClinicalTrial.gov number NCT03322592.).


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Neoplasias Pancreáticas/patologia , Avaliação Rápida no Local , Idoso , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
4.
Diagn Cytopathol ; 49(7): 856-863, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33885229

RESUMO

BACKGROUND: Information on whether a fine-needle biopsy (FNB) needle can improve histopathological specimen quality or the amount of core tissue collected in the diagnosis of subepithelial lesions (SELs) remains insufficient. In this study, we aimed to compare the procedure outcomes and adequacy of histopathological specimens of fine-needle aspiration (FNA) and FNB needles in endoscopic ultrasound-guided tissue acquisition (EUS-TA) using sample isolation processing by stereomicroscopy (SIPS) in patients with SELs. METHODS: We performed a retrospective comparison of SEL cases registered in two previously conducted prospective studies. Of 61 cases, we identified 56 cases of SELs that involved the muscularis propria layer. Of these, 27 patients who underwent EUS-TA using a 22-gauge FNA needle between July 2016 and December 2017, and 29 patients who underwent the procedure using a 22-gauge FNB needle between March 2018 and January 2019 were included in the FNA and FNB group, respectively. RESULTS: Patient background characteristics did not differ between the groups. The technical success rate was 100% in both groups. The median adequacy score was significantly higher in the FNB group than in the FNA group (P < .01). The histological diagnosis showed no significant difference in the accuracy rate between the groups. CONCLUSIONS: In EUS-TA using the SIPS procedure to target SELs derived from the muscularis propria layer, FNB needles collect more core tissues and significantly improve histopathological specimen quality compared with FNA needles. When combined with SIPS, a high tissue diagnosis rate may be obtained regardless of the type of puncture needle used.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Neoplasias Gastrointestinais/diagnóstico , Agulhas , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mucosa/cirurgia , Estudos Retrospectivos
5.
Medicine (Baltimore) ; 100(10): e25106, 2021 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-33725907

RESUMO

INTRODUCTION: Cytological study of samples obtained by Endoscopic ultrasound (EUS)-guided fine-needle aspiration (EUS-FNA) allows for recognition of clear signs of malignant transformation. However, certain neoplasms can be difficult to diagnose without histological analysis. Recently, a novel EUS-guided fine needle biopsy (EUS-FNB) needle was developed to increase tissue acquisition. This study set out to investigate the usefulness of this novel EUS-FNB needle (NEFN) in terms of obtaining a proper histology compared with a conventional EUS-FNA needle (CEFN). METHODS: This investigation was a prospective, single-blind, randomized study in a single academic hospital. Primary outcome was the acquisition rate of an appropriate and sufficient specimen for histologic assessment. Secondary outcomes were diagnostic yield of peripancreatic masses using a CEFN and a NEFN. Furthermore, we assessed the feasibility of determining K-ras mutation status according to needle type. RESULTS: The study enrolled 56 consecutive patients. Technical success rates were 96.6% (28/29) for the CEFN and 100% (27/27) for the NEFN (P = 1.000). No complications occurred during or after the procedure in either needle group. An adequate sample for cytologic diagnosis was obtained in 89.7% (26/29) of patients in the CEFN group vs 96.3% (26/27) of patients in the NEFN group (P = .612). For histologic diagnosis, a sample with a biopsy adequacy score of 2 or more was obtained in 41.4% (12/29) of CEFN-acquired samples vs 88.9% (24/27) of NEFN-acquired samples (P < .001). K-ras mutation analysis using histologic specimens was possible in 13 (44.8%) CEFN-acquired samples and 25 (92.6%) of NEFN-acquired samples. This difference was significant (P < .001). CONCLUSIONS: The present study suggests that the NEFN is an effective and reliable alternative compared to a CEFN in terms of tissue acquisition rate and quality of histologic sampling.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Agulhas , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Método Simples-Cego
6.
Histopathology ; 79(2): 252-259, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33657658

RESUMO

AIMS: Because serous cystadenoma (SCA) does not usually require excision, it is critical to distinguish it from differential diagnoses which do, especially neuroendocrine tumour (NET). The gold standard for diagnosing SCA is assessment of endoscopic ultrasound-guided fine needle aspiration/biopsy (EUS-FNAB) material. Inhibin immunohistochemistry aids this assessment, but such positivity is not absolutely sensitive or specific to SCA. The following is the largest known study of SCA EUS-FNAB specimens and the first to compare four potential SCA immunomarkers between themselves and inhibin, compared against NET. METHODS AND RESULTS: Immunohistochemistry for calponin, mucin 6 (MUC6), glucose transporter 1 (GLUT1) and vascular endothelial growth factor A (VEGFA) was performed on 30 EUS-FNAB and three resection specimens of SCA and 32 EUS-FNAB specimens of NET. GLUT1 and VEGFA were suboptimal as diagnostic immunomarkers of SCA, being expressed by 10 and 44% of NETs, respectively. Further, their expression by cellular constituents of blood which often contaminate EUS-FNAB specimens hampered identification of neoplastic cells, especially in hypocellular samples. While 19% of NETs showed nuclear MUC6 positivity, cytoplasmic expression of the protein showed 100% specificity and sensitivity as an SCA marker. However, assessing MUC6 in EUS-FNAB specimens must also consider the protein's focal expression in physiological pancreatic, gastric or duodenal tissues, which can contaminate these specimens. Calponin was less sensitive (71% versus 100%) but more specific (100% versus 91%) than inhibin, although easier to assess in EUS-FNAB specimens than MUC6. CONCLUSIONS: Of the four potential immunomarkers of SCA suggested by the existing literature, calponin and MUC6 are useful complementary studies to inhibin for application to EUS-FNAB specimens.


Assuntos
Proteínas de Ligação ao Cálcio/metabolismo , Cistadenoma Seroso/diagnóstico , Cistadenoma Seroso/imunologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Inibinas/metabolismo , Proteínas dos Microfilamentos/metabolismo , Mucina-6/metabolismo , Adolescente , Adulto , Idoso , Biomarcadores Tumorais , Proteínas de Ligação ao Cálcio/imunologia , Estudos de Coortes , Cistadenoma Seroso/patologia , Duodeno/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Feminino , Transportador de Glucose Tipo 1/metabolismo , Humanos , Imuno-Histoquímica , Inibinas/imunologia , Masculino , Proteínas dos Microfilamentos/imunologia , Pessoa de Meia-Idade , Tumores Neuroendócrinos/patologia , Pâncreas/patologia , Estômago/patologia , Sinaptofisina/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo
7.
Arq Bras Cir Dig ; 33(4): e1554, 2021.
Artigo em Inglês, Português | MEDLINE | ID: mdl-33503114

RESUMO

BACKGROUND: Fine needle biopsy (FNB) histological samples by endoscopic ultrasound. It is important to obtain representative histological samples of solid biliopancreatic lesions without a clear indication for resection. The role of new needles in such task is yet to be determined. AIM: To compare performance assessment between 20G double fine needle biopsy (FNB) and conventional 22G fine needle aspiration (FNA) needles for endoscopic ultrasound (EUS)-guided biopsy. METHODS: This prospective study examined 20 patients who underwent the random puncture of solid pancreatic lesions with both needles and the analysis of tissue samples by a single pathologist. RESULTS: The ProCore 20G FNB needle provided more adequate tissue samples (16 vs. 9, p=0.039) with better cellularity quantitative scores (11 vs. 5, p=0.002) and larger diameter of the histological sample (1.51±1.3 mm vs. 0.94±0.55 mm, p=0.032) than the 22G needle. The technical success, puncture difficulty, and sample bleeding were similar between groups. The sensitivity, specificity, and diagnostic accuracy were 88.9%, 100%, and 90% and 77.8%, 100%, and 78.9% for the 20G and 22G needles, respectively. CONCLUSIONS: The samples obtained with the ProCore 20G FNB showed better histological parameters; although there was no difference in the diagnostic performance between the two needles, these findings may improve pathologist performance.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/normas , Agulhas/classificação , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Agulhas/efeitos adversos , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico por imagem , Estudos Prospectivos , Sensibilidade e Especificidade , Adulto Jovem
8.
Expert Rev Gastroenterol Hepatol ; 15(7): 821-828, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33481633

RESUMO

OBJECTIVES: It is still unclear whether endoscopic ultrasound (EUS) contrast-enhanced fine-needle aspiration (CH-EUS-FNA) determines superior results in comparison to standard EUS-FNA in tissue acquisition of pancreatic masses. Aim of this meta-analysis was to compare the diagnostic outcomes of these two techniques. METHODS: We searched the PubMed/Medline and Embase database through October 2020 and identified 6 studies, of which 2 randomized controlled trials (recruiting 701 patients). We performed pairwise meta-analysis through a random effects model and expressed data as odds ratio (OR) and 95% confidence interval (CI). RESULTS: Pooled diagnostic sensitivity was 84.6% (95% CI 80.7%-88.6%) with CH-EUS-FNA and 75.3% (67%-83.5%) with EUS-FNA, with evidence of a significant superiority of the former (OR 1.74, 95% CI 1.26-2.40; p < 0.001). Subgroup analysis confirmed the superiority of CH-EUS-FNA over EUS-FNA only in larger lesions. Pooled diagnostic accuracy was 88.8% (85.6%-91.9%) in CH-EUS-FNA group and 83.6% (79.4%-87.8%) in EUS-FNA group (OR 1.52, 1.01-2.31; p = 0.05). Pooled sample adequacy was 95.1% (91.1%-99.1%) with CH-EUS-FNA and 89.4% (81%-97.8%) with EUS-FNA (OR 2.40, 1.38-4.17; p = 0.02). CONCLUSION: CH-EUS-FNA seems to be superior to standard EUS-FNA in patients with pancreatic masses. Further trials are needed to confirm these results.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Pâncreas/patologia , Neoplasias Pancreáticas/patologia , Meios de Contraste , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Humanos , Manejo de Espécimes
9.
Dig Dis Sci ; 66(9): 3171-3178, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33078322

RESUMO

BACKGROUND: Cutting needles are thought to be effective as biopsy needles. A few types of cutting needles are available for endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), and the Menghini-type needle is an end-type cutting needle. AIMS: A prospective randomized controlled trial was conducted to compare the results of EUS-FNA using a Menghini-type needle (needle M) versus a conventional needle (needle S). METHODS: The main eligibility criteria were as follows: patients with a pancreatic mass referred for EUS-FNA, ≥ 20 years old, and a performance status < 4. The primary outcome was the sample quality. The secondary outcomes were factors associated with the sample quality, diagnostic accuracy, and adverse events. RESULTS: A total of 97 patients were enrolled in this study. The sample quality for total puncture with needle M (92.8%) was significantly higher than that with needle S (81.4%) (p = 0.0305). The tumor size (p = 0.033) and type of needle (p = 0.031) were significant factors associated with adequate tissue collection in univariate and multivariate analyses (odds ratio [OR] 2.71; 95% confidence interval [CI] 1.12-6.54; p = 0.027 for tumor size, and OR 2.93; 95% CI 1.23-8.21; p = 0.0153 for type of needle). The diagnostic accuracy of each needle was 88.7% (86/97) with needle M and 73.2% (71/97) with needle S. Adverse events occurred in 2 of the 97 patients (0.02%). CONCLUSION: A Menghini-type needle was able to obtain core tissue for histology more effectively than a conventional aspiration needle. TRIAL REGISTRATION NUMBERS: UMIN registration number of 000020668.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Agulhas/efeitos adversos , Neoplasias Pancreáticas , Manejo de Espécimes , Idoso , Estudos Cross-Over , Diagnóstico Diferencial , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Desenho de Equipamento , Feminino , Humanos , Masculino , Teste de Materiais/métodos , Avaliação de Processos e Resultados em Cuidados de Saúde/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Manejo de Espécimes/métodos , Manejo de Espécimes/normas
10.
Dig Dis Sci ; 66(5): 1700-1706, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32556821

RESUMO

BACKGROUND: EUS-guided liver biopsy (EUS-LB) has been shown to be a safe and effective alternative to percutaneous liver biopsy. The optimal needle device and technique for EUS-LB is still evolving. The aim of this study was to compare the efficacy of two second-generation 19G fine-needle biopsy (FNB) (Franseen- and Fork-tip) devices for EUS-LB. METHODS: This is a repeated-measure crossover study with a prospectively maintained cohort of patients. We performed EUS-LB with a one-pass and single-actuation method using two 19G FNB needles in 22 consecutive patients between 10/2018 and 9/2019. Patients were randomized to left vs right liver lobes to be biopsied as well as the needle sequence. The specimens obtained were evaluated for adequacy for histologic diagnosis. The primary outcome was number of complete portal tracts (CPTs), post-fix aggregate, and longest specimen length. Secondary outcomes were prefix aggregate specimen length and the specimen adequacy judged by two expert pathologists. RESULTS: A total of 44 liver biopsies were performed in 22 patients. The CPTs were higher in the Franseen-tip needle group compared to the Fork-tip needle group (14.4 vs 9.5, p = 0.043). Post-fix aggregate specimen length (44.9 mm vs 34.6 mm, p = 0.097), the post-fix longest specimen length (19.9 mm vs 13.7 mm, p = 0.175), and prefix aggregate specimen length (51.7 mm vs 45 mm, p = 0.265) were not significantly different. Both needles showed similarly high histologic adequacy (100% vs 95.5%, p = 0.312). Interestingly, the right of the liver showed higher yield of CPTs with both needles (Franseen, 16.2 vs. 12.8, p = 0.003, the Fork-tip, 12.8 vs. 7.0, p < 0.0001). CONCLUSION: EUS-guided liver biopsy using the 19G Franseen-tip needle may provide more CPTs than 19G Fork-tip needle on a single-pass, single-actuation comparison.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Hepatopatias/patologia , Fígado/patologia , Agulhas , Estudos Cross-Over , Desenho de Equipamento , Feminino , Humanos , Fígado/diagnóstico por imagem , Hepatopatias/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos
11.
Respir Investig ; 59(2): 235-239, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33187889

RESUMO

BACKGROUND: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive hilar mediastinal node sampling technique used for lung cancer staging and diagnosis of lesions. Besides the conventional 22-gauge (G) and 21G needles, a 25G needle is now available for this procedure. The objective of this study was to evaluate the efficacy of the 25G EBUS-TBNA needle. METHODS: We retrospectively reviewed consecutive patients who underwent EBUS-TBNA using both 22G and 25G aspiration needles from January 2017 through December 2017 at St. Marianna University School of Medicine. We identified 10 patients and compared the diagnostic yield and the sample volume for each needle. RESULTS: Six patients were diagnosed with lung cancer and four with sarcoidosis. Total diagnostic yield was 80% (8/10) for the 22G and 60% (6/10) for the 25G (P = 0.31). In patients with lung cancer, the diagnostic yield was 67% (4/6) for the 22G and 83% (5/6) for the 25G (P = 0.50). In patients with sarcoidosis, the diagnostic yield was 100% (4/4) for the 22G and 25% (1/4) for the 25G (P = 0.07). In patients with lung cancer, the median tissue area was comparable for each needle; however, in patients with sarcoidosis, the sample area was smaller for the 25G than for the 22G. We did not encounter any major complications or bleeding during EBUS-TBNA procedures. CONCLUSIONS: Although histologic specimens obtained by the 25G needle are expected to be useful for the diagnosis of lung cancer, we found the 25G needle inadequate for diagnosing sarcoidosis due to insufficient sample size.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Pulmão/patologia , Agulhas , Manejo de Espécimes/métodos , Adulto , Idoso , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Feminino , Humanos , Neoplasias Pulmonares/complicações , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sarcoidose Pulmonar/complicações
12.
J Am Soc Cytopathol ; 9(5): 389-395, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32680792

RESUMO

Endoscopic ultrasound-guided tissue acquisition is now an imperative technique for the diagnosis of multiple diseases in the gastrointestinal tract and nearby structures. Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) and fine needle biopsy via dedicated FNB needles (EUS-FNB) are two standard-essential tools for tissue acquisition. The choice of needle type is an important factor determining appropriate tissue acquisition. Multiple studies have compared EUS-FNA versus EUS-FNB on different lesions also there are several studies evaluated different needles in terms of sampling adequacy and cytological and histological accuracy. Prior studies comparing prior-generation FNB needles to FNA did not show an increased diagnostic yield with FNB. However, the newer-generation needles have demonstrated enhanced performance compared with their predecessors. As they may provide a large amount of tissue for the cytological and histological evaluation, rapid onsite specimen evaluation (ROSE), and immunohistochemical and molecular analyses, which may be very important for targeted therapy. In this review, we discuss current evidence and literature on the use of the newer generation needles for pancreatic and non-pancreatic lesions.


Assuntos
Pancreatite Autoimune/diagnóstico por imagem , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Neoplasias Gastrointestinais/diagnóstico por imagem , Linfoma/diagnóstico por imagem , Agulhas/classificação , Neoplasias Pancreáticas/diagnóstico por imagem , Pancreatite Autoimune/patologia , Neoplasias Gastrointestinais/patologia , Trato Gastrointestinal/patologia , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Linfoma/patologia , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Neoplasias Pancreáticas/patologia
13.
Monaldi Arch Chest Dis ; 90(3)2020 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-32696627

RESUMO

Endobronchial ultrasound has revolutionized the field of bronchoscopy and has become one of the most important tools for the diagnosis of intrathoracic lymphadenopathy and para-bronchial structures. The reach of this technique has not been limited to these structures and pleural lesions have been at times accessible. To our knowledge, pleural fluid collections have not been accessed with endobronchial ultrasound (EBUS) through oesophageal approach and rationale behind using this approach. We report a case of 70 years old man who has been referred from physician for the EBUS in view of hilar mass with mediastinal lymphadenopathy with pleural effusion. The endobronchial ultrasound through oesophagus (EUS-B) was done for thoracocentesis and lymph node cytology evaluation and ultimately endobronchial biopsy of hilar mass was done as rapid on-site (ROSE) analysis of lymph node was suggestive of necrotic tissue. The cytology report of lymph node and pleural effusion was positive for malignant cells. The final diagnosis was metastatic poorly differentiating adeno-squamous carcinoma.


Assuntos
Carcinoma Adenoescamoso/secundário , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Endossonografia/métodos , Esôfago/cirurgia , Neoplasias Pulmonares/patologia , Idoso , Broncoscopia/métodos , Carcinoma Adenoescamoso/diagnóstico , Humanos , Linfonodos/citologia , Linfonodos/patologia , Linfadenopatia/complicações , Linfadenopatia/patologia , Metástase Linfática/patologia , Masculino , Mediastino/patologia , Derrame Pleural/diagnóstico , Derrame Pleural/etiologia , Toracentese/métodos
14.
Ultrasound Med Biol ; 46(9): 2453-2463, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32546410

RESUMO

The ultrasonic visibility of a biopsy needle tip is of critical importance for the success and safety of endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) procedures. The aim of this study was to design a surface topology, in silico, which enhances the ultrasound visibility of a needle by controlling and optimising the direction of the reflections. Topographic enhancements to needle surface redirect scattered waves back to the transducer to enhance needle visibility, or "echogenicity." Echogenicity enhancement is demonstrated across insonification angles of 30°-90° on full-length scale of biopsy needles used in practice. By applying a textured surface across the full length of the needle surface, the signal being returned to the transducer can be tripled from that of a constant periodic dimple echogenic surface and seven times that of an untextured flat surface. Our first principles model provides a quantitative insight to echogenicity and its enhancement. The model allows in silico design of needles for USG-FNA and biopsy with enhanced echogenicity and consequent improvement in visibility, including but not limited to needle tip area.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Agulhas , Ultrassonografia , Desenho de Equipamento
15.
J Am Soc Cytopathol ; 9(4): 249-253, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32451285

RESUMO

INTRODUCTION: Adequate sampling by endobronchial ultrasound (EBUS)-transbronchial needle aspiration to meet the demands of precision medicine or histologic evaluation is challenging. There is increasing demand for core biopsy specimens with advances in therapy. Franseen enodoscopic ultrasound needles have shown promising results in gastroenterology application for obtaining core biopsies and same design has recently been extended for pulmonary use. We evaluated Franseen needles with EBUS to assess its utility, safety and ability to provide core biopsy specimens. MATERIALS AND METHODS: Retrospective analysis of our database at the University of Utah of patients undergoing EBUS with a Franseen needle was performed to ascertain the performance characteristics of this needle in the first 100 patients after its implementation. Medical records were also reviewed to identify any immediate procedure-related complications. RESULTS: One hundred seventy locations were sampled in 100 patients. A total of 152 lymph nodes and 18 masses were sampled. Core biopsies, as per pathology report, were seen in 87% of patients. A clinically concordant pathological diagnosis was established in 97% of patients. Diagnostic yield for granulomatous lymphadenopathy was 95.6% (22 of 23). No patient-related adverse events were noted. CONCLUSION: The Franseen needle evaluated in this study can safely procure core tissue samples during EBUS bronchoscopy that are adequate for histopathological diagnosis in benign and malignant lesions. Its ability to provide adequate tissue in patients with granulomatous inflammation is encouraging.


Assuntos
Broncoscopia/métodos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Endossonografia/métodos , Linfonodos/diagnóstico por imagem , Linfadenopatia/diagnóstico por imagem , Agulhas/efeitos adversos , Idoso , Biópsia com Agulha de Grande Calibre , Feminino , Humanos , Linfonodos/patologia , Linfadenopatia/patologia , Masculino , Pessoa de Meia-Idade , Patologistas/psicologia , Segurança do Paciente , Medicina de Precisão/métodos , Estudos Retrospectivos
16.
J Bronchology Interv Pulmonol ; 27(4): 253-258, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32282445

RESUMO

BACKGROUND: The Japan Society for Respiratory Endoscopy performed a nationwide survey to evaluate the current status and complications of bronchoscopy. Data on deaths due to bronchoscopy, complications after bronchoscopy, and particularly, complications of forceps biopsy were surveyed. METHODS: The survey form was mailed to 532 facilities accredited by the society. The numbers of procedures, complications, and deaths were investigated. RESULTS: The response rate was 79.1% (421 facilities). Deaths attributable to diagnostic bronchoscopy occurred in 11 (0.011%) of 98,497 cases.In regards to forceps biopsy, the guide sheath method was applied in 23,916 cases and the conventional method in 31,419 cases was done with conventional method. Complications of forceps biopsy developed in 1019 cases in total, with an incidence rate of 1.84%. The most frequent complication was pneumothorax (0.70%), followed by pneumonia/pleurisy (0.46%) and hemorrhage (0.45%). The incidence of hemorrhagic complication was significantly lower in the guide sheath group than in the non-guide sheath group (0.29% vs. 0.58%; P<0.001). The overall incidence of complications (1.63% vs. 2.00%; P=0.002) and the mortality rate (0% vs. 0.02%; P=0.04) were significantly lower in the guide sheath group. CONCLUSION: The incidence of hemorrhagic complications in forceps biopsy of peripheral pulmonary lesions was lower when the guide sheath method was applied. It is necessary to increase the awareness for safety control in diagnostic bronchoscopy for new procedures.


Assuntos
Broncoscopia/efeitos adversos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Hemorragia/epidemiologia , Biópsia Guiada por Imagem/efeitos adversos , Neoplasias Pulmonares/patologia , Instrumentos Cirúrgicos/efeitos adversos , Broncoscopia/métodos , Broncoscopia/mortalidade , Broncoscopia/estatística & dados numéricos , Endoscopia , Hemorragia/etiologia , Hemorragia/mortalidade , Humanos , Incidência , Japão , Mortalidade/tendências , Pleurisia/epidemiologia , Pleurisia/etiologia , Pneumonia/epidemiologia , Pneumonia/etiologia , Pneumotórax/epidemiologia , Pneumotórax/etiologia , Estudos Retrospectivos , Sociedades Médicas/organização & administração , Inquéritos e Questionários/estatística & dados numéricos
18.
United European Gastroenterol J ; 8(3): 314-320, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32213013

RESUMO

BACKGROUND: The use of 19-gauge (G) stainless steel needles for endoscopic ultrasound-guided fine-needle biopsy of a pancreatic mass often results in technical difficulties due to an inability to advance the relatively rigid needle out of the endoscope. More flexible nitinol-based needles might decrease such technical difficulties and thus increase diagnostic accuracy. OBJECTIVE: In this prospective multicenter randomized single-blinded study we compared the diagnostic value of those two needle types in patients with a solid pancreatic lesion. METHODS: Patients with a solid pancreatic mass were diagnosed with endoscopic ultrasound-guided fine-needle biopsy using one puncture with each needle in a randomized fashion. The primary endpoint was the diagnostic accuracy of each needle. Secondary endpoints included time for puncture, amount of tumour tissue obtained, and technical failure. Histological specimens were centrally reviewed by a pathologist blinded to the final needle type and final diagnosis (ClinicalTrials.gov Identifier: NCT02909530). RESULTS: Out of 46 prospectively recruited patients, central pathological examination was available for 41. Diagnostic accuracy for the two needles combined was 87.8%. Diagnostic accuracy was 66% and 68% using the stainless steel- and nitinol-based needle respectively. Time spent for puncturing was 137 ± 61 s (mean ± standard deviation) for the stainless steel and 111 ± 53 s for the nitinol-based needle (p = 0.037). Technical failure occurred in three (6.5%) cases using the stainless steel- and in none using the nitinol-based needle. CONCLUSIONS: Usage of a nitinol-based 19-G needle failed to present a significant superior accuracy compared with a stainless steel needle in endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic lesions.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Agulhas , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligas , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/patologia , Estudos Prospectivos , Aço Inoxidável
19.
Clin Respir J ; 14(7): 675-682, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32162471

RESUMO

INTRODUCTION: Endobronchial biopsy using forceps is generally performed with a standard bronchoscope, while a needle is used with an endobronchial ultrasound (EBUS) bronchoscope. An EBUS video bronchoscope, such as the EB-530US instrument (Fujifilm, Tokyo, Japan), provides good visibility and may, therefore, enable both forceps biopsies and needle aspirations to be performed. OBJECTIVES: The aim of this study was to investigate the feasibility of performing forceps biopsies and needle aspirations using the EBUS video bronchoscope for diagnosing endobronchial lesions. METHODS: Seventy patients with suspected endobronchial lesions based on a computed tomography scan were recruited and underwent forceps biopsy using the EB-530US EBUS bronchoscope. If the result of a rapid on-site cytological evaluation was negative, an additional needle aspiration of the same lesion or other target lesions was performed. The primary outcome was the completion rate of bronchoscopy, using only the EBUS bronchoscope without removal. RESULTS: In the 70 patients, forceps biopsies and/or needle aspirations using the EBUS video bronchoscope were performed and completed without removing the EBUS bronchoscope in 67 patients (95.7%). The remaining three patients required the removal of the EBUS bronchoscope from the trachea (blood clot obstruction of the working channel in one patient and change to a thin bronchoscope to sample an EBUS bronchoscope-inaccessible lesion in two others). The EBUS bronchoscope provided diagnostic material in 66 patients (94.3%). One case each of bleeding and pneumonia were observed (1.4%). CONCLUSION: Both forceps biopsy and needle aspiration are feasible using a Fujifilm EB-530US EBUS video bronchoscope.


Assuntos
Broncopatias/diagnóstico por imagem , Broncoscopia/métodos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Endossonografia/instrumentação , Neoplasias Pulmonares/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia/estatística & dados numéricos , Biópsia/tendências , Broncopatias/patologia , Broncoscopia/normas , Desenho de Equipamento/métodos , Desenho de Equipamento/estatística & dados numéricos , Estudos de Viabilidade , Feminino , Humanos , Japão/epidemiologia , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
20.
Cir Cir ; 88(1): 27-33, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31967618

RESUMO

BACKGROUND: There are different techniques for obtaining tissue using a fine needle guided by endoscopic ultrasound (EUS); all aim to obtain the most appropriate material, free of defects, of good quality and in sufficient quantity. OBJECTIVE: The objective of the study was to determine which of the two EUS-guided techniques (capillary and wet) provides better quality samples for cytopathological analysis and which should be used for obtaining tissue from pancreatic, bile duct, liver, and lymph node tumors. MATERIAL AND METHODS: We conducted a pilot prospective study that included 26 patients with evidence of pancreatic tumor, liver tumor, and/or lymph node metastasis of primary tumor. All patients were subjected to two different tissue sampling techniques, the capillary technique and the wet technique, during the same procedure. Both techniques relied on EUS guidance. The samples obtained for the cytopathological analysis were evaluated in blinded manner by two different pathologists. RESULTS: Pathologist A was able to make a diagnosis using the capillary technique in 96.15% of the cases and in 88.46% of the cases using the wet technique. Pathologist B was able to make a diagnosis using the capillary technique in 96.15% of the cases and in 92.30% of the cases using the wet technique. The kappa coefficient between observers for histopathological diagnosis was 1 for capillarity and 0.948 for wet technique. CONCLUSION: The capillary technique yielded better results than the wet technique in terms of sample quality and cellularity.


ANTECEDENTES: Existen diferentes técnicas para la obtención de tejido usando la aguja fina guiada por ultrasonido endoscópico. Todas ellas pretenden obtener el tejido mas apropiado, libre de defectos, con una buena calidad y una cantidad suficiente. OBJETIVO: Determinar cuál de las dos técnicas guiadas por ultrasonido endoscópico (capilar y húmeda) proporciona mejor calidad de la muestra para análisis citopatológico y biopsia de tejido pancreático, vías biliares, hígado y tumores de nodos linfáticos. MÉTODO: Estudio piloto, prospectivo, que incluyó 26 pacientes con evidencia de tumor pancreático, hepático o metástasis de nodos linfáticos. Durante el mismo procedimiento, los pacientes fueron sometidos a las dos técnicas de obtención de muestra tisular guiadas por ultrasonido endoscópico. Las muestras para el análisis citopatológico fueron evaluadas de forma cegada por dos patólogos diferentes. RESULTADOS: El patólogo A pudo hacer el diagnóstico usando la técnica de capilaridad en el 96.15% de los casos y en el 88.46% cuando se usó la técnica húmeda; el patólogo B realizó el diagnóstico en el 96.15% y el 92.30% de los casos, respectivamente. El coeficiente kappa entre los observadores para el diagnóstico histopatológico fue de 1 para la técnica de capilaridad y de 0.948 para la técnica húmeda. CONCLUSIÓN: La técnica de capilaridad mostró mejores resultados en términos de calidad de la muestra y celularidad.


Assuntos
Neoplasias dos Ductos Biliares/patologia , Colangiocarcinoma/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Endossonografia/métodos , Neoplasias Hepáticas/patologia , Neoplasias Pancreáticas/patologia , Adenocarcinoma/patologia , Adulto , Idoso , Biópsia por Agulha Fina/instrumentação , Biópsia por Agulha Fina/métodos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Endossonografia/instrumentação , Feminino , Humanos , Fígado/patologia , Neoplasias Hepáticas/secundário , Metástase Linfática/patologia , Masculino , Pessoa de Meia-Idade , Pâncreas/patologia , Projetos Piloto , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...